Siglent SVA1075X 9kHz to 7.5GHz Spectrum / Vector Network Analyser + FREE VNA & TG Licence

£6616.00 (Β£7939.20 inc VAT)

Description

Siglent SVA1075X Spectrum Analyser – Comes with VNA Software Licence as standard!

The SVA1075X is a Spectrum and Vector Network Analyser with a frequency range up to 7.5GHz. Siglent Technologies has introduced a new product for its line of RF instrumentation to meet the growing need for higher bandwidths in testing circuit designs for 5G applications. This new analyser represents the highest bandwidth product to date for Siglent Technologies and can also be extended with Vector Signal Analysis and other options to increase versatility for meeting the unique challenges of RF circuit design.

Purchase of SVA mechanical calibration kit recommended for VNA use

  • Spectrum Analyser Frequency Range: 9kHz – 7.5GHz
  • Vector Network Analyser Frequency Range: 100kHz – 7.5GHz
  • Resolution Bandwidth: 1Hz – 3MHz
  • Displayed Average Noise Level: -165dBm/Hz
  • SSB Phase Noise: <-98dBc/Hz
  • Total Amplitude Accuracy: <0.7dB
  • Tracking Generator: 100kHz – 7.5GHz
  • VNA Measurement Vector S11, Vector S21
  • Distance to Fault: VNA Timing Domain Analysis Locator
  • Touch Screen: Multi Touch, Mouse and Keyboard supported
  • Advanced Measurement: CHP, ACPR, OBW, CNR, Harmonic, TOI, Monitor
  • Reflection Measurement: VSWR Measurement using Reflection Bridge
  • EMI Test: EMI Filter and Quasi-Peak Detector, Log Scale and Limit Line
  • Modulation Analysis: AM, FM, ASK, FSK, MSK, PSK, QAM
  • Communication Interface: LAN, USB Device, USB Host (USB-GPIB)
  • Remote Control Capability: SCPI/Labview/IVI based on USB-TMC/VXI-11/Socket/Telnet
  • Remote Controller: NI-MAX, Web Browser, Easy Spectrum Software, File Explorer

 

Product Videos

Documentation

Frequency
Frequency RangeSVA1015X: 9 kHz ~ 1.5GHz
SVA1032X: 9 kHz ~ 3.2GHz
SVA1075X: 9 kHz ~ 7.5GHz
Frequency ResolutionΒ 1 Hz
Frequency Span
Range0 Hz, 100 Hz to Max Frequency
AccuracyΒ± Span / (number of display points – 1)
Internal Reference Source
Reference frequency10.000000 MHz
Reference frequency
accuracy / uncertainty
Β± [(time since last adjustment Γ— frequency aging rate) + temperature
stability + initial calibration accuracy]
Initial calibration accuracy<1 ppm
Temperature stability<1 ppm/year, 0 Β°C ~50 Β°C
Frequency aging rate<0.5 ppm/first year, 3.0 ppm/20 years
Marker
Marker resolutionSpan / (number of display points – 1)
Marker uncertaintyΒ± [frequency indication Γ— reference frequency uncertainty + 10% Γ—
resolution bandwidth + Β½ * marker resolution + 1 Hz]
Frequency Counter resolutionSVA1015X: 0.01 Hz
SVA1032X: 0.01 Hz
SVA1075X: 0.1 Hz
Bandwidths
Resolution bandwidth (-3dB)SVA1015X: 1 Hz ~ 1 MHz, in 1-3-10 sequence
SVA1032X: 1 Hz ~ 1 MHz, in 1-3-10 sequence
SVA1075X: 1 Hz~3 MHz
Resolution filter shape factor< 4.8 : 1 (60 dB:3 dB), Gaussian-like
RBW uncertainty<5%
Video bandwidth (-3dB)SVA1015X: 1 Hz ~ 3 MHz, in 1-3-10 sequence
SVA1032X: 1 Hz ~ 3 MHz, in 1-3-10 sequence
SVA1075X: 1 Hz~10 MHz
VBW uncertainty<5%
Sweep and Trigger
Sweep timeSVA1015X: 1ms to 1500s
SVA1032X: 1ms to 3200s
SVA1075X: 1ms to 7500s
RBWSweep 30 Hz ~ 1 MHz; 30 Hz ~ 1 MHz; 3 kHz ~ 3 MHz
FFT 1 Hz ~ 10 kHz; 1 Hz ~ 10 kHz; 1 Hz ~ 10 kHz
Sweep ruleSingle, Continuous
Trigger sourceFree, Video, External
External trigger5V TTL level, Rising edge/Falling edge
Amplitude and Level
Measurement rangeDANL to +10 dBm, 100 kHz ~ 1 MHz, Preamp off
DANL to +20 dBm, 1 MHz ~ 7.5 GHz, Preamp off
Reference level-200 dBm to +30 dBm, 1 dB steps
Preamplifier20 dB (nom.)
Input attenuation0 ~ 30 dB, 1 dB steps, 0 ~ 50 dB, 1 dB steps
Maximum input DC voltage+/- 50 VDC
Maximum average power30 dBm, 3 minutes, fc β‰₯10 MHz, att > 20 dBm, preamp off
Maximum damage level33 dBm, fc β‰₯ 10 MHz, att > 20 dBm, preamp off
Level Display
Logarithmic level axis1 dB to 200 dB
Linear level axis0 to reference level
Units of level axisdBm, dBmV, dBΞΌV, dBΞΌA, Volt, Watt
Number of display points751
Number of traces4
Trace detectorsPositive-peak, Negative-peak, Sample, Normal,
Average(Voltage/RMS/Video), Quasi-peak
Trace functionsClear write, Max Hold, Min Hold, View, Blank, Average, Math
General Specifications
SourceAC voltage range: 100-240 V, 50/60 Hz or 100-120 V 400 Hz;
Power consumptionSVA1015X: 35W
SVA1032X: 35W
SVA1075X: 70W
TemperatureWorking temperature: 0 Β°C to 40 Β°C,
Storage temperature: -20 Β°C to 70 Β°C
Humidity0 Β°C to 30 Β°C, ≀ 95% Relative humidity
30 Β°C to 50 Β°C, ≀ 75% Relative humidity
AltitudeOperating: less than 3 km
DisplayTFT LCD, 1024 Γ— 600, 10.1 inch multi-touch screen
StorageInternal (Flash) 256 MB, external (USB storage device) 32 GByte
Dimensions393 mm Γ— 207 mm Γ— 116.5 mm (WΓ— HΓ— D)
WeightSVA1015X: Net:Β  4.30 kg (9.5 lb); Shipping: 5.10 kg
SVA1032X: Net: 4.40 kg (9.7 lb); Shipping: 5.20 kg
SVA1075X: Net:Β  4.70 kg (10.4 lb); Shipping: 5.50 kg

Note*

Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.

You may also like…

Optional Accessories …