Siglent SSG6485A 4 Channel, 9 kHz-20 GHz Analogue Signal Generator

.

Available on back-order

Description


Siglent SSG6485A 4 Channel, 9 kHz-20 GHz Analogue Signal Generator

The SSG6M80A series comprises multi-channel, phase-coherent analogue signal generators in dual- and four-channel models, with frequency coverage from 9 kHz to 20 GHz. A shared high-stability master clock and trigger system provides true inter-channel phase coherence, while each channel offers independent frequency, amplitude, and phase control. The series also delivers excellent long-term phase stability and includes a phase-memory function. With ultra-low phase noise, a wide output power range, high signal purity, and flexible modulation capabilities, the SSG6M80A is suited to demanding applications, including beamforming, phased-array systems, MIMO testing, differential signal generation, and multi-tone measurements.

Key Features
  • Frequency up to 13.6 GHz/20 GHz
  • 0.001 Hz frequency setting resolution
  • Phase Noise: -135 dBc / Hz @ 1 GHz, 10 kHz offset (typ.)
  • Level error≤ 0.7 dB(typ)
  • Provides FM, PM analog modulation with internal, external or Int + Ext source
  • Single pulse, double pulse and pulse train generator (option)
  • The power meter control kit can easily use the power meter to measure power, control power output and correct line loss
  • Independently adjustable frequency, amplitude and phase per‑channel
  • Enables intra‑device channel‑to‑channel phase coherence and inter‑device cross‑channel phase coherence.
  • Phase‑coherent mode: 10 GHz carrier, ±2 °C temp change, 5‑h observation, phase fluctuation <1.5°
  • Features phase‑memory capability
  • Standard interface includes USB Host, USB Device (USB TMC), LAN (VXI-11, Socket, Telnet). Optional interface: GPIB
Applications
  • Beamforming and Phased Array
  • MIMO Applications
  • Differential Signal Drive
  • Multi-Tone and Nonlinearity Test

Product Images

Traditional single-channel generators struggle to maintain consistent phase relationships when multiple signals are required. The SSG6M80A addresses this challenge by integrating multiple channels in a single instrument that share a common high-stability clock reference and trigger system. This architecture enables true inter-channel phase coherence while still allowing independent control of frequency, amplitude, and phase on each channel. Phase drift between channels remains below ±1.5° over 10 hours across the full bandwidth under typical laboratory temperature conditions, ensuring phase stability for long-duration testing.
The SSG6M80A delivers excellent long-term phase stability and includes a phase-memory function that restores the original phase state after frequency changes. Multiple units can also be synchronized by connecting the master’s 10 MHz and 1 GHz reference outputs to the corresponding inputs on the slave units, expanding the channel count for larger test systems. These capabilities make the SSG6M80A particularly suitable for beamforming, phased-array evaluation, MIMO testing, differential signal generation, and multi-tone measurements.
Phase noise is typically below –135 dBc/Hz at a 1 GHz carrier with a 10 kHz offset. Combined with excellent harmonic and spurious suppression, the generators produce clean signals suitable for high-sensitivity receiver testing and high-linearity component characterization.
The SSG6M80A delivers excellent power output performance, supporting a wide output range from –110 dBm to +25 dBm while maintaining high output power across the entire frequency range. Typical level accuracy is below 0.7 dB, and standard power meter control enables closed-loop levelling, automatic cable-loss compensation, and flatness correction, ensuring accurate and repeatable power delivery in multi-port and wide-dynamic-range test setups.
The SSG6M80A supports FM and PM analogue modulation with internal, external, or combined modulation sources. Optional pulse modulation and a pulse-train generator allow users to create single, double, or fully customized pulse sequences with adjustable width, period, and repetition counts, as well as flexible step or list sweeps supporting up to 65,535 points.

Product Videos

Documentation

Frequency characteristics
Frequency
Frequency range SSG6283A / SSG6483A CW MODE 9 kHz-13.6 GHz
SSG6285A/ SSG6485A CW MODE 9 kHz-20 GHz
Frequency resolution 0.001 Hz
Setting time <10 ms(typ) ALC ON
<20 ms(typ)ALC OFF(S&H)
Phase resolution 0.1°
Frequency band [1]
Band Frequency range N
1 9 kHz ≤f≤250 MHz 1/8
2 250 MHz<f≤ 500 MHz 1/32
3 500 MHz<f≤ 1000 MHz 1/16
4 1000 MHz<f<1500 MHz 1/8
5 1500 MHz ≤f<3000 MHz 1/4
6 3000 MHz ≤f≤ 6000 MHz 1/2
7 6000 MHz<f≤ 12000 MHz 1
8 12000 MHz <f≤ 20000 MHz 2
[1] Frequency modulation-related parameter factor.
Frequency Reference
Standard
Reference frequency 10.000000 MHz
Initial calibration accuracy ±100 ppb
Temperature stability ±1 ppb, 0℃~50℃
Frequency ageing rate 50 ppb/ year
Frequency sweep
Sweep type Frequency step (linear or logarithmic step)
arbitrary list
Sweep range Full frequency range
Sweep shape Triangle, saw-tooth
Sweep mode Single, continuous
Step spacing Linear, logarithmic
Number of points Step sweep 2-65535
List sweep 1-500
Dwell time range 10 ms-100 s
Dwell time setting resolution 0.1 ms
Trigger source Auto, keyboard, external connector, bus (GPIB, USB, LAN)
Trigger slope Positive, negative (when trigger source is external)
Phase specifications
Phase Adjustment Range 0~360° or -180° ~ 180°
Relative Phase Stability
Between Channels,5‑h observation,
±2 °C temp change
9 kHz-5 GHz <1° 5GHz-10GHz<1.5° 10G-20GHz < 2.5°

 

You may also like…