Siglent SSA3032X 9kHz to 3.2GHz Spectrum Analyser + FREE TG Licence

£1980.00 (Β£2376.00 inc VAT)

Description

Siglent SSA3032X Spectrum Analyser

The SSA3021X has a frequency range of 9kHz to 3.2GHz and a Minimum Resolution Bandwidth of 1Hz. Siglent’s SSA3000X family of spectrum analysers offer a frequency range of 9kHz to 2.1/3.2 GHz. With their light weight, small size, and friendly user interface, the SSA3000s present a large, bright, easy to read display, powerful and reliable automatic measurements, and plenty of impressive features. Applications include research and development, education, production, maintenance, and pre-compliance testing.

  • All-Digital IF Technology
  • Frequency Range from 9 kHz to 2.1/3.2 GHz
  • -161 dBm/Hz Displayed Average Noise Level (Typ.)
  • -98 dBc/Hz @10 kHz Offset Phase Noise (1 GHz, Typ.)
  • Total Amplitude Accuracy < 0.7 dB
  • 1 Hz Minimum Resolution Bandwidth (RBW)
  • Tracking generator (TG) is currently included at no charge

Product Videos

Documentation

Frequency Characteristics
Frequency
Frequency RangeSSA3021X: 9kHz-2.1GHz. SSA3032X: 9kHz-3.2GHz
Frequency Resolution1Hz
Frequency Span
RangeSSA3021X: 0 Hz, 100 Hz to 2.1 GHz.  SSA3032X: 0 Hz, 100 Hz to 3.2 GHz
Accuracy± Span / (number of sweep points – 1)
Internal Reference Source
Reference frequency10.000000 MHz
frequency reference accuracy± [(time since last adjustment × frequency aging rate) + temperature stability + calibration accuracy]
Initial calibration accuracy<1 ppm
Temperature stability<1 ppm/year, 0 ℃ ~50 ℃
Frequency aging rate<0.5 ppm/first year, 3.0 ppm/20 years
Marker
Marker resolutionSpan / (number of sweep points – 1)
Marker uncertainty± [frequency indication × frequency reference uncertainty + 1% × span + 10% × resolution bandwidth + marker resolution]
Frequency counter resolution1 Hz
Frequency counter uncertainty± [frequency indication × frequency reference accuracy + counter resolution]
Bandwidths
Resolution bandwidth (-3dB)1 Hz~1 MHz*, in 1-3-10 sequence
Resolution filter shape factor< 4.8:1 (60 dB:3 dB), Gaussian-like
RBW uncertainty<5%
Video bandwidth (-3dB)1 Hz ~3 MHz, in 1-3-10 sequence
VBW uncertainty<5%
Amplitude Characteristics
Measurement rangeDANL to +10 dBm, 100 kHz~1 MHz, preamplifier off
DANL to +20 dBm, 1 MHz~3.2 GHz, preamplifier off
Reference level-100 dBm to +30 dBm, 1 dB steps
Preamplifier20 dB (nom.), 9 kHz~3.2 GHz
Input attenuation0~51 dB, 1 dB steps
Maximum input DC voltage+/- 50 VDC
Maximum average RF power30 dBm, 3 minutes, fc≥10 MHz, attenuation >20 dBm, preamp off
Maximum damage level33 dBm, fc≥10 MHz, attenuation >20 dBm, preamp off
Phase Noise
Phase noise<-95 dBc/Hz @10 kHz offset, <-98 dBc/Hz (typ.)
<-96 dBc/Hz @100 kHz offset,<-97 dBc/Hz (typ.)
<-115 dBc/Hz @1 MHz offset, <-117 dBc/Hz (typ.)
Level Display
Logarithmic level axis10 dB to 200 dB
Linear level axis0 to reference level
Units of level axisdBm, dBmV, dBμV, dBμA, V, W
Number of display points751
Number of traces4
Trace detectorsPositive-peak, Negative-peak, Sample, Normal, Average (Voltage/RMS/Video) , Quasi-peak (with EMI option)
Trace functionsClear write, Max Hold, Min Hold, View, Blank, Average
Frequency Response
Preamp Off±0.8 dB,
±0.4 dB, (typ.)
Preamp On±0.9 dB,
±0.5 dB, (typ.)
Error and Accuracy
Resolution bandwidth switching
uncertainty
10 kHz RBW
Logarithmic resolution ±0.2 dB, liner resolution ±0.01, nominal
Input attenuation switching
uncertainty
20 ℃ to 30 ℃ , fc = 50 MHz, preamp off, Relative to 20 dB, 1 to 51 dB attenuation
±0.5 dB
Absolute amplitude accuracy20 ℃ to 30 ℃ , fc = 50 MHz, RBW = 1 kHz, VBW = 1 kHz, peak detector, attenuation = 20 dB, 95th percentile reliability

preamp off ±0.4 dB, input signal -20 dBm

preamp on ±0.5 dB, input signal -40 dBm

Total amplitude accuracy20 ℃ to 30 ℃ , Fc>100 kHz, input signal -50 dBm~0 dBm, RBW = 1 kHz, VBW = 1 kHz, peak detector, attenuation = 20 dB, preamp off, 95th percentile reliability ± 0.7 dB
RF input VSWRinput attenuation 10 dB, 1 MHz~3.2 GHz <1.5, nom
Distortion and Spurious Responses
Second harmonic distortionfc≥50 MHz, mixer level -30dBm, attenuation = 0 dB, preamp off, 20 ℃ to 30 ℃ , typ.
-65 dBc
Third-order interceptfc≥50 MHz, two -20 dBm tones at input mixer spaced by 100 kHz, attenuation = 0 dB, preamp off, 20 ℃ to 30 ℃ , typ.
+10 dBm
1dB Gain Compressionfc≥50 MHz, attenuation = 0 dB, preamp off, 20 ℃ to 30 ℃ , nom.
>-5 dBm
Residual responseinput terminated = 50 Ω,attenuation = 0 dB, 20 ℃ to 30 ℃ , typ.
<-90 dBm
Input related spuriousMixer level = -30 dBm, 20 ℃ to 30 ℃
<-65 dBc
General Specifications
DisplayTFT LCD, 1024×600(waveform area 751×501), 10.1 inch
StorageInternal (Flash) 256 MByte, External (USB storage device) 32 GByte
SourceInput voltage range (AC) 100 V~240 V, AC frequency supply 45 Hz~440 Hz, Power consumption 30 W
TemperatureWorking temperature 0 ℃ to 50 ℃ , Storage temperature -20 ℃ to 70 ℃
Humidity0 ℃ to 30 ℃ , ≤95% Relative humidity;
30 ℃ to 50 ℃ , ≤75% Relative humidity
Dimensions393 mm×207 mm×116.5 mm (W×H×D)
WeightContain tracking generator 4.60 kg (10.1 lb)