Kikusui SD009-PCR-LE/WE Power Line Disturbance Immunity Testing Software IEC61000-4

£562.00 (Ā£674.40 inc VAT)

SKU: SD009-PCR-LE/WE Category:

Description


Kikusui SD009-PCR-LE/WE Power Line Disturbance Immunity Testing Software


ā€œQuick Immunity Sequencerā€ (model name: SD009-PCR-LE/WE) is an application software for immunity testing with the AC/DC power supply PCR-WE/WE2 series system, based on the power line disturbance standard (IEC61000-4 Series) for the immunity testing of the EMC standard. Not only can it be used for compliance testing based on the latest standards or for some types of preliminary testing, but the software can be also employed for advance checking in development phases and for immunity margin tests, because it allows extended testing conditions to be set as needed.

 

*Note: To use this software, the firmware version of the PCR-LE must be 2.0 or later.

List of conformance to the EMC standard tests
āœ” :Conforming as standard ā–² :Partially non-conforming ā”€ :Function not available

 

 

 

 

Standard Item Single-Phase Conforming Three-Phase Conforming
IEC61000-1-11
Voltage dips, short interruptions and voltage variations
Voltage Dips āœ” āœ”
Short Interruptions āœ” āœ”
Voltage Variations āœ” āœ”
IEC61000-4-13
Harmonics and inter-harmonics
Flat curve āœ” āœ”
Over swing āœ” āœ”
Frequency sweep āœ” āœ”
Odd harmonics the order of which is not a multiple of 3 āœ” āœ”
Odd harmonics the order of which is a multiple of 3 āœ” āœ”
Even harmonics āœ” āœ”
Interharmonics āœ” āœ”
Meister curve āœ” āœ”
IEC61000-4-14
Voltage fluctuation
Voltage fluctuation āœ” āœ”
Interval āœ” āœ”
IEC61000-4-17
Ripple on DC input power port
Single-phase rectifier circuit āœ” ā”€
Three-phase rectifier circuit āœ” ā”€
IEC61000-4-27
Unbalance in units
Unbalance ā”€ ā–²*1
IEC61000-4-28
Variation of power frequency for equipment with 16 A/phase
Frequency variation āœ” āœ”
IEC61000-4-29
Voltage dips, short interruptions and voltage variations on DC
Voltage dips āœ” ā”€
Short interruptions ā–²*3 ā”€
Voltage variations āœ” ā”€
IEC61000-4-34
Voltage dips, short interruptions and voltage variations for equipment with input current more than 16 A/phase
Voltage dips ā–²*2 ā–²*2
Short interruptions ā–²*2 ā–²*2
Voltage variations āœ” āœ”

* Immunity testing for units with 16 A/phase except for those required by IEC61000-4-34
*1. Capability of rapid change with 1 Āµs to 5 Āµs is required for 110 %, 95.2 %, 93.5 %, 90 %, 87 %, 80 %, 74 %, 71 %, 66 %. Preliminary test is capable since the voltage response of the PCR-WE/WE2 is 55 Āµs in FAST mode.
*2. The device between the range of 16 A to 75 A requires to have the capability of rapid change with 1 Ī¼s to 5 Ī¼s. The device exceeding 75 A does not require to have the capability of rapid change with 1Ī¼s to 5 Ī¼s. (It is relaxed to 1 Āµs to 50 Āµs for the device exceeding 75 A.)
*3. Must support output impedance greater than 100 kĪ©. The PCR-WE/WE2 output impedance is less than 100 kĪ© and therefore designed for preliminary testing purposes.