Siglent SVA1032X 9kHz to 3.2GHz Spectrum / Vector Network Analyser + FREE VNA & TG Licence

£2698.00 (Β£3237.60 inc VAT)

EMC Pre-compliance Offer
Purchase SIGLENT spectrum analyser and SRF5030T near-field probe kit* and receive a free EMI option activation license!
Offer from 01 Oct 23 to 30th June 24

Description

Siglent SVA1032X Spectrum Analyser – Comes with Vector Network Analysis as standard

The SVA1032X is a Spectrum and Vector Network Analyser with a frequency range up to 3.2GHz. The SIGLENT SVA1000X series spectrum & vector network analysers are powerful and flexible tools for RF signal and network analysis. With a frequency range to 3.2 GHz, the analyser delivers reliable automatic measurements and multiple modes of operation: the base model are a spectrum analyser and a vector network analyser, optional functions include a distance-to-fault locator, a vector signal analyser. Applications include broadcast monitoring/evaluation, site surveying, S-parameter measurement, cable and antenna testing, analogue/digital modulation analysis, EMI pre-compliance test, research and development, education, production, and maintenance.

Purchase of SVA mechanical calibration kit recommended for VNA use

  • Tracking Generator Standard
  • Distance To Fault (Opt.)
  • Vector Network Analysis (Std.)
  • Vector Signal Modulation Analysis (Opt.)
  • EMI Filter and Quasi-Peak Detector Kit (Opt.)
  • Advanced Measurement Kit (Opt.)
  • 10.1 lnch Multi-Touch Screen , Mouse and Keyboard supported
  • Web Browser Remote Control on PC and Mobile Terminals and File Operation

 

Product Videos

Documentation

Frequency
Frequency Range SVA1015X: 9 kHz ~ 1.5GHz
SVA1032X: 9 kHz ~ 3.2GHz
SVA1075X: 9 kHz ~ 7.5GHz
Frequency Resolution Β 1 Hz
Frequency Span
Range 0 Hz, 100 Hz to Max Frequency
Accuracy Β± Span / (number of display points – 1)
Internal Reference Source
Reference frequency 10.000000 MHz
Reference frequency
accuracy / uncertainty
Β± [(time since last adjustment Γ— frequency aging rate) + temperature
stability + initial calibration accuracy]
Initial calibration accuracy <1 ppm
Temperature stability <1 ppm/year, 0 Β°C ~50 Β°C
Frequency aging rate <0.5 ppm/first year, 3.0 ppm/20 years
Marker
Marker resolution Span / (number of display points – 1)
Marker uncertainty Β± [frequency indication Γ— reference frequency uncertainty + 10% Γ—
resolution bandwidth + Β½ * marker resolution + 1 Hz]
Frequency Counter resolution SVA1015X: 0.01 Hz
SVA1032X: 0.01 Hz
SVA1075X: 0.1 Hz
Bandwidths
Resolution bandwidth (-3dB) SVA1015X: 1 Hz ~ 1 MHz, in 1-3-10 sequence
SVA1032X: 1 Hz ~ 1 MHz, in 1-3-10 sequence
SVA1075X: 1 Hz~3 MHz
Resolution filter shape factor < 4.8 : 1 (60 dB:3 dB), Gaussian-like
RBW uncertainty <5%
Video bandwidth (-3dB) SVA1015X: 1 Hz ~ 3 MHz, in 1-3-10 sequence
SVA1032X: 1 Hz ~ 3 MHz, in 1-3-10 sequence
SVA1075X: 1 Hz~10 MHz
VBW uncertainty <5%
Sweep and Trigger
Sweep time SVA1015X: 1ms to 1500s
SVA1032X: 1ms to 3200s
SVA1075X: 1ms to 7500s
RBW Sweep 30 Hz ~ 1 MHz; 30 Hz ~ 1 MHz; 3 kHz ~ 3 MHz
FFT 1 Hz ~ 10 kHz; 1 Hz ~ 10 kHz; 1 Hz ~ 10 kHz
Sweep rule Single, Continuous
Trigger source Free, Video, External
External trigger 5V TTL level, Rising edge/Falling edge
Amplitude and Level
Measurement range DANL to +10 dBm, 100 kHz ~ 1 MHz, Preamp off
DANL to +20 dBm, 1 MHz ~ 7.5 GHz, Preamp off
Reference level -200 dBm to +30 dBm, 1 dB steps
Preamplifier 20 dB (nom.)
Input attenuation 0 ~ 30 dB, 1 dB steps, 0 ~ 50 dB, 1 dB steps
Maximum input DC voltage +/- 50 VDC
Maximum average power 30 dBm, 3 minutes, fc β‰₯10 MHz, att > 20 dBm, preamp off
Maximum damage level 33 dBm, fc β‰₯ 10 MHz, att > 20 dBm, preamp off
Level Display
Logarithmic level axis 1 dB to 200 dB
Linear level axis 0 to reference level
Units of level axis dBm, dBmV, dBΞΌV, dBΞΌA, Volt, Watt
Number of display points 751
Number of traces 4
Trace detectors Positive-peak, Negative-peak, Sample, Normal,
Average(Voltage/RMS/Video), Quasi-peak
Trace functions Clear write, Max Hold, Min Hold, View, Blank, Average, Math
General Specifications
Source AC voltage range: 100-240 V, 50/60 Hz or 100-120 V 400 Hz;
Power consumption SVA1015X: 35W
SVA1032X: 35W
SVA1075X: 70W
Temperature Working temperature: 0 Β°C to 40 Β°C,
Storage temperature: -20 Β°C to 70 Β°C
Humidity 0 Β°C to 30 Β°C, ≀ 95% Relative humidity
30 Β°C to 50 Β°C, ≀ 75% Relative humidity
Altitude Operating: less than 3 km
Display TFT LCD, 1024 Γ— 600, 10.1 inch multi-touch screen
Storage Internal (Flash) 256 MB, external (USB storage device) 32 GByte
Dimensions 393 mm Γ— 207 mm Γ— 116.5 mm (WΓ— HΓ— D)
Weight SVA1015X: Net:Β  4.30 kg (9.5 lb); Shipping: 5.10 kg
SVA1032X: Net: 4.40 kg (9.7 lb); Shipping: 5.20 kg
SVA1075X: Net:Β  4.70 kg (10.4 lb); Shipping: 5.50 kg

Note*

Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.

You may also like…

Optional Accessories …